Place of Origin: | China |
Brand Name: | Tianan Power |
Certification: | ISO9001,IEC |
Model Number: | DFT6-40.5 |
Minimum Order Quantity: | 10 unit |
---|---|
Price: | Pending |
Packaging Details: | Wooden Case |
Delivery Time: | 60 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 100 sets/year |
Rated Voltage: | 40.5kV | Shell Material: | Aluminum Alloy |
---|---|---|---|
Insulation Medium: | SF6 | Rated Frequency: | 50Hz |
Altitude: | Within 1000m | Ambient Temperature Range: | -25℃~+40℃ |
Product Name: | DFT6-40.5 Series Cable Distribution Box | Application: | Power Distribution |
High Light: | 40.5kV power distribution cabinet,630A power distribution cabinet,DFT6 cable distribution box ODM |
DFT6-40.5 Series Cable Distribution Box
General of DFT6-40.5 Series Cable Distribution Box
The cable distribution box is a transfer station for transmitting electrical energy from the cable, and is used for outdoor connection, tapping, branching, reattaching or conversion of the cable line. It has the characteristics of simple, convenient, flexible, fully insulated, fully sealed structure, waterproof, corrosion-resistant, anti-pollution, maintenance-free, safe and reliable.
DFT6-40.5 series cable distribution box is a new type of power supply equipment designed by our factory to cooperate with 40.5kV power network cable system. It is widely used in cable nodes in 40.5kV system as the acceptance and distribution of electric energy. This series of cable distribution boxes has a unique structure and beautiful appearance, and is especially suitable for urban streets, residential quarters, high-rise buildings, airports, docks and other places with small construction area and relatively high environmental requirements.
DFT6-40.5 Series Cable Distribution Box Type designation
Service condition of DFT6-40.5 Series Cable Distribution Box
When transcend the above service condition or has special requirement, users can negotiate with us to solve.
DFT6-40.5 cable distribution box (consist of enclosure and cabinet inside)
Name | Unit | Parameter | |
Rated voltage | kV | 40.5 | |
Rated frequency | HZ | 50 | |
Lightning impulse withstand voltage between phases, to earth / isolation fracture | kV | 185/215 | |
1 min power frequency withstand voltage between phases, to earth/ isolation fracture | kV | 95/118 | |
Load switch | Rated current | A | 630 |
Rated thermal current (2S) | kA | 20 | |
Rated dynamic current (peak) | kA | 50 | |
Rated short-circuit making current (peak) | kA | 50 | |
Mechanical life | Time | 5000 | |
Busbar side of grounding switch | Rated thermal current (2S) | kA | 20 |
Rated dynamic current (peak) | kA | 50 | |
Rated short-circuit making current (peak) | kA | 50 | |
Mechanical life | Time | 2000 | |
Grounding circuit | Rated thermal current (2S) | kA | 17.4 |
Rated dynamic current (peak) | kA | 43.5 | |
Fuse | Rated current | A | 50 |
Rated breaking current | kA | 31.5 | |
Protection level | Main circuit (load switch and grounding switch) | IP5X | |
Fuse and cable connection | IP4X | ||
Fuse and cable room | IP3X | ||
SF6 gas rated pressure (environment temperature: 20℃) | Mpa | 0.04 | |
SF6 gas Min. service pressure ( environment temperature: 20℃) | 0.02 | ||
SF6 gas yearly leakage rate | % | ≤1 | |
SF6 gas moisture content(V/V) | ppm | ≤400 | |
Transfer current | A | 1000 |
Foundation of DFT6-40.5 Series Cable Distribution Box (only for reference)
Contact Person: admin
Tel: +8613858385873