Place of Origin: | China |
Brand Name: | Tianan Power |
Certification: | ISO9001,IEC |
Model Number: | GCS |
Minimum Order Quantity: | 10 unit |
---|---|
Price: | Pending |
Packaging Details: | Wooden Case |
Delivery Time: | 60 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 100 sets/year |
Product Name: | GGD AC Low Voltage Indoor Metal Clad Switchgear | Material: | Galvanized Steel Or Aluminum |
---|---|---|---|
Rated Voltage: | 380V | Color: | As Required |
Rated Frequency: | 50/60Hz | Rated Insulation Voltage: | 660/1000V |
Protection Degree: | IP3L0.IP4L0 | Warranty: | 2 Years |
High Light: | GGD Metal Clad Switchgear,60Hz Metal Clad Switchgear,380V power distribution cabinet |
GGD AC Low Voltage Indoor Metal Clad Switchgear
Purpose of GGD AC Low Voltage Indoor Metal Clad Switchgear
As the power, lightening, electrical energy transferring, distributing and controlling of distribution equipment, GGD AC L.V. Distribution Switchboard is applicable to the AC 50HZ, rated voltage of 380V and rated current of 3150A distribution system in the Power Plant, Substation, Workshop and Mines.
It conforms to the IEC439 “L.V. completed switchgear and controlling equipment” and GB7251 “L.V. completed switchgear”. It has the good capability of breaking, dynamic thermal stability, new and reasonable structure, perfect electrical design. It can be used widely in high level of protection and so on. It also can be used for the updated and replaced products.
GGD AC Low Voltage Indoor Metal Clad Switchgear Type designation
GGD AC Low Voltage Indoor Metal Clad Switchgear Service condition
·Ambient temperature should not be more than +40℃ and no less than -5℃, average temperature should not be more than +35℃ within 24 hrs.
·For the indoor installation,elevation above the sea should not exceed 2000m.
·The Ambient relative humidity at Max. temperature +40℃ should not be 50%, but can be bigger at lower temperature(such as 90% at +20℃). The consideration about the condensed dew should be taken with the change of temperature.
·The sloping angle should not be more than 5 degree with the vertical side during the installation.
·The equipment should be installed at the place without the stronger vibration and impact, the surrounding dielectric should be no corrosive metal, harmful gas and conducting dielectric.
Parameter of GGD AC Low Voltage Indoor Metal Clad Switchgear
Type | Rated voltage V | Rated current A | Rated short-circuit breaking voltage KV | 1S rated withstanding current KA | Rated peak withstanding current KA |
GGD1 | 380 | 400—1000 | 15 | 15 | 30 |
GGD2 | 380 | 1000—1500 | 30 | 30 | 63 |
GGD3 | 380 | 2000—3150 | 50 | 50 | 105 |
Contact Person: admin
Tel: +8613858385873