Place of Origin: | China |
Brand Name: | Tianan Power |
Certification: | ISO9001,IEC |
Model Number: | XGN75-12(Z) |
Minimum Order Quantity: | 10 unit |
---|---|
Price: | Pending |
Packaging Details: | Wooden Case |
Delivery Time: | 60 work days |
Payment Terms: | L/C, T/T |
Supply Ability: | 100 sets/year |
Product Name: | Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z) | Rated Voltage: | 12KV |
---|---|---|---|
Rated Current: | 630, 1250, 2000, 2500, 3150KV | Rated Frequency: | 50Hz |
Altitude: | ≤4000m | Medium Material: | SF6 Gas |
Application: | Indoor | Type: | Fixed Type And Box Type |
High Light: | Gas Insulated Switchgear 3150KV,Gas Insulated Switchgear XGN75,outdoor medium voltage switchgear 4000m |
Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z)
General of Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z)
XGN75-12 (Z) Indoor gas insulation metal-clad switchgear is designed and developed by our company self and adopted permanent magnet mechanism vacuum circuit breaker as main switch and HV live conductor is full-enclosed in SF6 room. It is suitable as a new generation metal-clad switchgear automatic-distribution, compact and able to extend.
This switchgear conforms to IEC 62271-200 and all primary components employed therein are in accordance with the relevant standards.
It is designed to accommodate high performance vacuum circuit breaker (VCB) which has been designed and tested in accordance with IEC62271-100.
The switchgear panels are suitable for the assembly of single &double busbar systems for indoor installation.
Characteristic of Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z)
1. Reliable
Each compartment is monitored individually &has its own pressure relief device.
Use of Vacuum circuit breakers with high number ofmechanical & electrical operations
Robust interlocking system
2. Safety
The primary side components are hermetically enclosed, gas filled compartment and thus insensitiveto atmosphere, dirt &dust.
Current transformer are mounted outside the gas compartment & mounted on earthed LV compartment
3. Space saving
Smaller foot prints. All operations on the switchgear front
4. Economically efficient
Reduced space & surface area requirement.
Long service life
Maintenance free Gas compartment
Technical data of Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z)
S/N | Item | Unit | Data | |
1 | Rated voltage | kV | 12 | |
2 | Rated current | A | 630 1250 2000 2500 3150 | |
3 | Rated frequency | Hz | 50 | |
4 | Rated power frequency withstand voltage (1 min) | Phase to phase, phase to earth | kV | 42 |
Insulation distance | 48 | |||
7 | Rated lightning impulse withstand voltage | Phase to phase, phase to earth | kV | 75 |
Insulation distance | 85 | |||
10 | Power frequency withstand voltage of auxiliary control circuit (1 min) |
V | 2000 | |
11 | Rated short-cricuit breaking current (rms) | kA | 25 31.5 40 | |
12 | Rated short-circuti making current | kA | 63 80 100 | |
13 | Rated short time withstand current | kA/s | 25/4 31.5/4 40/4 | |
14 | Rated peak withstand current | kA | 63 80 100 | |
15 | Degree of protection | Gas-filled compartment : IP67 LV compartment: IP4X |
||
16 | Every phase main return circuit resistance | uΩ | <250 | |
17 | Rated SF6 gas pressure (20ºC) | Mpa | 0.045 | |
18 | Min SF6 gas pressure (20ºC) | Mpa | 0.03 | |
19 | Annual SF6 gas loss rate | % | ≤0.5 | |
20 | Rated voltage of auxiliary control circuit | V | DC 110/220 AC 220 |
|
21 | Dimensions (WxDxH) | mm | 500x1200x2300 |
Operation procedure of Indoor Gas Insulation Metal-clad Switchgear (C-GIS), XGN75-12(Z)
Power transmission operation: (circuit breaker is closing and three-position disconnector is earthing):
Power off overhauling operation
Measure outlet cable after confirmed it loses electricity and then the circuit breaker could be closed.
Contact Person: admin
Tel: +8613858385873