Product Name: | Medium Voltage Switchgear, KYN28A-24KV, Metal-enclosure AC Switchgear | Rated Voltage: | 24KV |
---|---|---|---|
Busbar: | 3-phase 4-wire | Voltage Level: | Medium Voltage |
Degree Of Protection: | IP4X | Ambient Air Temperature: | -10°C~+40°C |
Application: | Indoor | Altitude: | ≤1000m |
High Light: | 24KV electrical distribution cabinet,3 phase electrical distribution cabinet,1250A outdoor type switchgear Metal enclosure |
Medium Voltage Switchgear, KYN28A-24KV, Metal-enclosure AC switchgear
General of Medium Voltage Switchgear, KYN28A-24KV, Metal-enclosure AC switchgear
>> Ratings: system voltage 24KV,rated current up to 4000A,
AC three phase 50/60HZ.
>> Application: mainly applicable in the power plant, substation, mineral enterprise to receive and
Distribute power with the functions of controlling, protecting and monitoring. It also can be
used in places where the frequently operations are in need.
>> Standard: IEC62271-200.
Technical parameter Medium Voltage Switchgear, KYN28A-24KV, Metal-enclosure AC switchgear
Item | Unit | Data | |
Rated voltage (Maximum operating voltage) |
kV | 24 | |
Rated insulation level | 1min kV rms | kV | 65 |
Lightning impulse withstand voltage | kV | 125 | |
Rated frequency | Hz | 50/60 | |
Main busbar rated current | A | 630,1250,1600,2000,2500,3150 | |
Branch Bus Wire Rated Current | A | 630,1250,1600,2000,2500,3150 | |
4s Thermal stability current (virtual value) | kA | 16,20,25,31.5 | |
Rated machine-stability current (peak value) * |
kA | 40,50,63,80 | |
Protection degree | IP4X |
Features of Medium Voltage Switchgear, KYN28A-24KV, Metal-enclosure AC switchgear
a. The product is designed to combined structure, and assembled with rivet nut and high-strength bolt connection. The enclosure is made of aluminized zinc steel plate with 2mm thickness imported from Switzerland. Shutter is made of high quality cold-roll steel sheets and adopts resin powder electrostatic spraying process. It has attractive appearance, convenient installation and maintenance.
b. The panel is processed and bended through the imported numerical control equipment, so that the switchgear is lower than the same kinds of switchgear in weight and better in mechanical strength. The enclosure is IP4X in protection class. The switchgear has high accuracy, and is convenient for assembly and material unification.
c. HV compartments are isolated from each other. Each HV compartment is equipped with pressure relief plate on the top to ensure internal arc fault has no impact on the neighbor compartments and guarantee the security of the equipment and personnel.HV and LV compartments of switchgear are sealed well. There is self-heating device in the HV compartment to ensure the surface of insulator is dry in switchgear.
d. The door of switchgear can be opened. In order to ensure personnel security, all normal operations including open and close of circuit breaker, operation of pushing circuit breaker handcart to “on” position, operation of withdrawing to “test” or “disconnecting” position, and open and close of earthing switch are required to be done when the doors of HV compartment are closed.
e. The switchgear is divided into handcart room, busbar room, cable room, relay room and control room. There is metal earthing shutter at back of handcart room. After withdrawing handcart, the shutter will be closed automatically. The secondary contacts will be open or closed when the handcart is in or out. Busbar room is separated from other rooms. Cable room is located at back bottom of switchgear, which will be convenient for arrangement of incoming and outgoing cables. At bottom of cable room, there are a earthing busbar. Relay room and control room are located at former top of switchgear.
f. When the horizontal clapboard and the clapboard in busbar room are drawn, it will be very convenient to connect main busbar, install and maintain cable, earthing switch, lightning arrester, CT, etc on the front of switchgear.
g. Switchgear panel is equipped with observation window through which “on” or “off” button of circuit breaker handcart and mechanical position indicator can be observed, as well as energy stored or energy released of spring indicators. The observation window also can be used to open and close circuit breaker and store energy manually.
h. The handcart matches with insulating parts of switchgear, interlocking is safe, reliable and flexible. Handcart has breaking, test, operating position in switchgear, all positions have locating device to ensure reliable interlocking.
i. Alive busbar adopts heat-shrinkable bushing set in the cubicle, the busbar is copper, and the junction is tinned
External dimension and weight of Medium Voltage Switchgear, KYN28A-24KV, Metal-enclosure AC switchgear
Height H(mm) | 2300 | |
Width W(mm) | Rated current of branch bus 630A~3150A | 1000 1200 |
Depth D(mm) | Cable incoming and outgoing | 1900 |
Overhead incoming and outgoing feeder | 2300 | |
Weight (kg) | 800-1200 |